One-pin event planner: restrooms, tent and permits
Updated • Published
RestroomTrailerHQ's one-pin event planner turns a guest count, date and venue into a restroom minimum (1 toilet per 100 guests, a common county and city event rule), an accessible-unit count (at least 5% of clustered portable units under the ADA Standards), a tent size band (about 10–12 sq ft per guest seated at rounds, 8–10 at banquet tables, 6–8 standing), a tent-permit flag (over 400 sq ft under IFC 3103.2 as adopted locally) and the restroom trailer fleets that can reach the venue. Rules of thumb, not legal advice.
Send this plan to fleets
Free. Listing fleets keep 100% of what you pay them. We never sell your details to unrelated companies.
Quick reference (works without JavaScript)
| Guests | Minimum toilets (1 per 100) | Accessible units if portable (5%, min 1) | Tent sq ft, rounds | Tent sq ft, banquet | Tent sq ft, standing |
|---|---|---|---|---|---|
| 50 | 1 | 1 | 500–600 | 400–500 | 300–400 |
| 100 | 1 | 1 | 1,000–1,200 | 800–1,000 | 600–800 |
| 150 | 2 | 1 | 1,500–1,800 | 1,200–1,500 | 900–1,200 |
| 200 | 2 | 1 | 2,000–2,400 | 1,600–2,000 | 1,200–1,600 |
| 250 | 3 | 1 | 2,500–3,000 | 2,000–2,500 | 1,500–2,000 |
| 300 | 3 | 1 | 3,000–3,600 | 2,400–3,000 | 1,800–2,400 |
| 400 | 4 | 1 | 4,000–4,800 | 3,200–4,000 | 2,400–3,200 |
| 500 | 5 | 1 | 5,000–6,000 | 4,000–5,000 | 3,000–4,000 |
Tent figures exclude dance floor, bar, buffet and stage. Every tent size in this table is over 400 sq ft, so check the permit rule below.
The rules behind the plan
- Restroom minimum: 1 toilet per 100 attendees, a common public-event rule: Maricopa County Environmental Health Code, Ch. II §VI, Reg. 5 (1 toilet per 100 persons at public gatherings); Calvert County, MD Special Event Manual, 2023 (1 portable restroom per 100; one ADA unit or 5%); City of Detroit Special Events Applicant Guide (1 portable restroom per 100 attendees). Your county, venue or health department may require more.
- Accessibility: U.S. Access Board, Guide to the ADA Standards, Chapter 6 (portable units: at least 5% of each cluster, §213.2 Exc. 3). Accessible units must be on an accessible route and marked with the International Symbol of Accessibility.
- Tent size: Peak Rentals seating chart (rounds 10–12, banquet 8–10, cocktail 6–8 sq ft per guest). Add space for everything else under the tent.
- Tent permit: IFC §3103.2 tent permit over 400 sq ft, as published in City of Napa tent permit information. Exceptions include open-sided tents up to 700 sq ft with 12 ft clearance. Adoption and amendments vary by city and state.
- Fleets in reach: the same straight-line distance and published-delivery-terms method as the delivery map.
Planning tools, not legal advice. Tents: TentRentalHQ.com • Restroom fleets: delivery map • Coverage: atlas